When pressed during the pump operation phase, it cyclically displays the programmed values on the
display; When pressed at the same time or keys, it increases or decreases a value
dependent on the selected operating mode. During programming it carries out an “enter” function,
meaning that it confirms entry to the various menu levels and modifications within the same.
Starts and stops the pump. In the event of a level alarm (alarm function only), flow alarm and active
memory alarm, it deactivates the signal on the display.
Used to “exit” the various menu levels. Before definitively exiting the programming phase, you will be
asked if you wish to save any changes
Used to run upwards through the menu or increase the numerical values to be changed. Can be used
to start dosage in Batch mode
Used to run downwards through the menu, or decrease the numerical values to be changed.
Electrical connections
1
Alarm relay
2
B 5
-Remote control input (start-stop)
-Pause signal input
6
9
Flow sensor input
10
You can access the programming menu by pressing the key for over three seconds. The keys
can be used to run through the menu items, with the key being used to access changes.
The pump is programmed in constant mode in the factory. The pump automatically returns to the operating mode
after 1 minute of no activity. Any data entered in these circumstances will not be saved.
The key can be used to exit the various programming levels. Upon exiting programming, the display will
show:
Exit Exit
Don’t Save ∇ ∆ Save to confirm the selection
PROG
" !
Paus Paragraph 17
Paragraph 11 [Link]
Main
Paragraph 12 Menu Paragraph 16
Paragraph 15
Paragrafo 13
Paragraph 14
Configuration
Pump Funtions
" !
Paragraph 9
Setting
Menu
Paragraph 10
Pump Functions
Paragrafo 1
" !
Pump Functions Pump Functions
Paragraph 2 Paragraph 8
Pump Functions
Functions Pump Functions
Paragraph 3
Menu Paragraph 7
Pump Functions
Paragraph 5
Pump Functions
Makes it possible to select the language. The pump is set in
! English in the factory.
Max flow rate
P100% Changes can be made by pressing the key, then
! using the keys to set the new value. Press
Alarm Relay
[Link]
Configuration The pump operates in constant mode. The flow can only be manually
Pump Funtions
Configuration
Pump Funtions The pump proportionally doses at a signal of (0)4-20 mA. On the basis of
the factory settings, the pump interrupts dosage at 4mA and doses at the
maximum set frequency when it receives 20 mA. These two values can be
" !
modified during programming. The maximum frequency can be modified
Pump Functions
0/4 - 20 mA
during operation, by pressing the keys at the same time to
0/4 - 20 mA
Low 4.0mA " !
increase the flow, or the keys to decrease it.
"
0/4 - 20 mA
High 20.0mA " !
"
mA F 4-20 Low 0
Lev Stop P100% 0.0 mA P100%
Current dosage value
(depends on the selected unit
Alarms and statuses Pump status of measurement)
• Lev = Level alarm • Empty = pump in start • Percentage, Frequency, Current dosage value
• Flw = Flow alarm • Stop = pump stationary • Makes it possible to modify the
l/h, Gph, ml/m
• Paus = pump in pause maximum dosage value by pressing
the + or – buttons at the same time
Configuration
Pump Funtions
The pump proportionally doses at a signal of 20-4(0) mA. On the basis of
the factory settings, the pump interrupts dosage at 20mA and doses at the
" ! maximum set frequency when it receives 4 mA. These two values can be
Pump Functions modified during programming. The maximum frequency can be modified
20-4/0 mA
"
Display during Operation Display during Setting (MODE key)
Operating mode
FLOW sensor Programmed value • Displays the Low and High • Input mA
Operating mode status • value
• Programmed interval value value in sequence
mA (default: 20-4)
mA F 20-4 High 0
Lev Stop P100% 0.0 mA P100%
Current dosage value
(depends on the selected unit
Alarms and statuses Pump status of measurement)
• Lev = Level alarm • Empty = pump in start • Percentage, Frequency, Current dosage value
• Flw = Flow alarm • Stop = pump stationary • Makes it possible to modify the
l/h, Gph, ml/m
• Paus = pump in pause maximum dosage value by pressing
the + or – buttons at the same time
Configuration
The pump doses in proportion to an external signal (i.e.: impulse launch
Pump Funtions counter). At every “n” signals, the pump makes a strike. You can set the
value of “n” during programming. By programming the value of “n” you set
" ! the maximum dosage %. This value can be modified during operation, by
Pump Functions
Divide (n:1) pressing the keys at the same time to increase the flow, or
Batch F M 7.0ml
Lev Stop 0 [Link] 7.0ml
Current dosage value 7.0ml
Alarms and statuses • Gradually displays
• Lev = Level alarm
• the dosed quantity
Flw = Flow alarm Pump status
• Mem = Memory alarm • Empty = pump in start Dosage value
• • The quantity can be modified by pressing the
Stop = pump stationary
• Paus = pump in pause + or – keys at the same time
Configuration
Pump Funtions
After receipt of the TRIGGER signal set, the pump doses a quantity
that can be programmed in ml. It is possible to set a delay time before
the dosing (Delay) and the interval between subsequent dosings
(Interv.) as illustrated in the diagram:
Trigger Quantity
PROG
Configuration
Delay Interv.
Configuration
Pump functions
By setting for example an Interval. time = 0, a system is obtained in
which the programmed quantity is dosed after each TRIGGER signal
- + (with any delay that has been set):
Pump functions
Time
Trigger Release
Time
Quantity 100ml - +
-
Time
Delay
[Link]
0.01.50 - +
- Delay Ritardo
Time
interv.
[Link]
0.01.50 - +
- It is possible to start the dosing by pressing the + key, which, in
Trigger Mode Trigger Mode
N. Open N. Open practice, simulates the Trigger signal.
-
Pause Input Mode
- The Trigger signal can be set to N. Open (it is activated when the
input passes from the open to the closed mode) or to N. Closed (it is
Trigger Mode
Trigger Mode N. Closed
activated when the input passes from the closed to the open mode).
- - The Trigger signal is locked during dosing (its receipt is neither stored
Trigger Mode
Disable nor managed).
The Pause (Remote input) input cannot be programmed and its
activation stops the dosing, while its further deactivation makes the
system wait again for the Trigger signal for a new dosing.
- +
Pum functions
Tempo
Delay Interv.
Time
Quantity 100ml - +
- The Delay and Interval times are in [Link] (days, hours,
minutes)
Time
Delay
[Link]
0.01.50 - +
- The Pause input can be programmed in three different modes:
Time
Interval
[Link]
0.01.50 - + 1. FreezeTime: when the pause is activated, the system cuts
- out the current time count and restarts it when the pause is
deactivated.
Trigger Mode
Disable - + 2. Pause Dosing: with the pause activated, the system
-
Pause Input Mode Pause Input Mode
continues to count time the and stops the dosing.
3. Restart Timer: when the pause is activated, the system
Restart Timer Restart Timer
stops the dosing and when the pause is deactivated the
- - count starts again from the beginning.
Pause Input Mode The dosage frequency can be modified while the pump is operating,
Freeze Time
Automatic Cal.
ml 20 ! "
Paragraph 12 - Statistics
Programming Operation
Alarm
by the flow sensor. Press the button to request the
Flow Off
maximum number of signals that the pump can recover
ESC
pressing the key. Press to return to the
Alarms
Level Alarm main menu
!
For adjusting the display contrast keep the key pressed and within 5 seconds press the keys or
to increase or decrease the contrast.
Alarms
Display Cause Interruption
Fixed alarm LED End of level alarm, without Restore the liquid level.
Flashing word “Lev” interrupting pump operation
I.e. Man
Lev P100%
Fixed alarm LED End of level alarm, with interruption Restore the liquid level.
Flashing words “Lev” and “stop” to pump operation
I.e. Man
Lev Stop P100%
Flashing word “Mem” The pump receives one or more
I.e. 1:n 6 pulses during dosage with memory Press the key
Mem function on Off
Flashing word “Mem” The pump receives one or more When the pump finishes receiving
I.e. 1:n M 6 pulses during dosage with memory external impulses, it returns the
Mem function on On memorized strokes
Fixed alarm LED Active flow alarm. The pump has
Flashing word “Flw” not received the programmed Press the key
I.e. Man F number of signals from the flow
Flw P100% sensor.
Internal CPU communication error.
I.e. Parameter Error Press the key to restore
PROG to default the default parameters.