PARAMETER MANUAL FOR

DYNACON VECTOR II
CONTROL VOLTAGE UNIT
D2R REV 5.2 CON3V040
DOC000992/1-EN / 25.09.2014

Original instructions
This document and the information contained herein, is the exclusive property of Konecranes Plc and represents a non-public, confidential and proprietary trade secret that may not be
reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of Konecranes Plc. Copyright © (2014) Konecranes Plc.
All rights reserved.
DOC000992/1-EN / 25.09.2014

Table of contents

1 GENERAL .................................................................................................................................................. 3
2 GROUP 1 MONITORING ........................................................................................................................... 4
2.1 Group 1 Monitoring ............................................................................................................................... 4
2.2 Group 1.7 Parameter Backup ............................................................................................................... 4
2.3 Group 1.8 Relay Output ........................................................................................................................ 4
2.4 Group 1.9 Operate Counters ................................................................................................................ 4
2.5 Group 1.10 Fault Counter ..................................................................................................................... 5
2.6 Group 1.11 Bus Control ........................................................................................................................ 5
2.7 Group 1.12 Service ............................................................................................................................... 5
2.8 Group 1.13 Multimonitor ....................................................................................................................... 6
3 GROUP 2 PARAMETERS ......................................................................................................................... 7
3.1 Group 2.1 Basic parameters ................................................................................................................. 7
3.2 Group 2.2 Bus Parameters ................................................................................................................... 8
3.3 Group 2.3 Protections ........................................................................................................................... 9
3.4 Group 2.4 Expert .................................................................................................................................. 9
3.5 Group 2.5 Laboratory ......................................................................................................................... 10
4 GROUP 5 SYSTEM MENU ...................................................................................................................... 12
4.1 Basic information ................................................................................................................................ 12
4.2 Group S5.3 Copy Parameters ............................................................................................................ 12
4.3 Group S5.4 Parameter Comparison ................................................................................................... 12
4.4 Group S5.5 Security ........................................................................................................................... 12
4.5 Group S5.6 Keypad Settings .............................................................................................................. 13
4.6 Group S5.7 Hardware Settings........................................................................................................... 13
4.7 Group S5.8 System Info ..................................................................................................................... 13

2/15
This document and the information contained herein, is the exclusive property of Konecranes Plc and represents a non-public, confidential and proprietary trade secret that may not
be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of Konecranes Plc. Copyright © (2014)
Konecranes Plc. All rights reserved.
DOC000992/1-EN / 25.09.2014

1 GENERAL
This manual describes parameters of DynACon. Parameters are assorted to groups. All groups are not
always visible from control panel. Groups are shown in control panel according to password level and
selected functions. This feature makes the visible parameter menu simple because only needed parameters
are shown.
The letter front of the code number describes variable type.

A = Application E = Expander M = Menu Group S = System


B = Button G = Group N = Multimonitor T = Trip Counter
C = Counter H = Fault History P = Parameter V = Value
D = Data I = Info R = Reference

3/15
This document and the information contained herein, is the exclusive property of Konecranes Plc and represents a non-public, confidential and proprietary trade secret that may not
be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of Konecranes Plc. Copyright © (2014)
Konecranes Plc. All rights reserved.
DOC000992/1-EN / 25.09.2014

2 GROUP 1 MONITORING

2.1 Group 1 Monitoring

G1 Monitoring
Code Name Description Unit
V1.1 Output Voltage Output voltage. V
V1.2 Output Current Output current. A
V1.3 Output Frequency Output Frequency. Hz
V1.4 DC Link Voltage Measured DC link voltage. V
V1.5 Unit Temperature Unit Temperature. °C
V1.6 Power Output power. kW

2.2 Group 1.7 Parameter Backup

G1.7 Parameter Backup


Par code Par name Description
B1.7.1 Load Default Par Restores Default Parameters to Active Parameters from the Control Unit memory. Default
Parameters are the parameters that have been saved in the factory.
B1.7.2 Save User Par Saves Active Parameters in the Control Unit as User Parameters. Final parameters for the
application must be saved as User Parameters after start-up.
B1.7.3 Load User Par Restores User Parameters to Active Parameters from the control unit memory. User
Parameters are the parameters that have been saved after start-up.

G1.7.4 Factory Default ≥ Expert password


Par code Par name Description
B1.7.4.1 Save Default Par Saves Active Parameters in the Control Unit as Default Parameters. Default Parameters
are the parameters that have been saved in the factory. For factory use only.

2.3 Group 1.8 Relay Output

G1.8 Relay Output


Par code Par name Description
V1.8.1 ROB1 state Shows a state of the relay output.
Relay is active when fault is on.
V1.8.2 ROB2 state Shows a state of the relay output.
Relay is active when drive is in RUN state.

2.4 Group 1.9 Operate Counters

G1.9 Operate Counters


Par code Par name Description
V1.9.1 Output MWh Amount of electric energy fed to the load.
V1.9.2 Runtime Unit run time hours (0.00h).

4/15
This document and the information contained herein, is the exclusive property of Konecranes Plc and represents a non-public, confidential and proprietary trade secret that may not
be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of Konecranes Plc. Copyright © (2014)
Konecranes Plc. All rights reserved.
DOC000992/1-EN / 25.09.2014

2.5 Group 1.10 Fault Counter

G1.10 Fault Counter


Par code Par name Description
V1.10.1 F1 Overcurrent Overcurrent fault counter
V1.10.2 F2 Overvoltage Overvoltage fault counter
V1.10.3 F3 Earth Fault Earth Fault fault counter
V1.10.4 F7 Saturation Saturation fault counter
V1.10.5 F9 Undervoltage Undervoltage fault counter
V1.10.6 F10 Input Phase Input Phase fault counter
V1.10.7 F11 Output Phase Output Phase fault counter
V1.10.8 F13 Undertemp Undertemperature fault counter
V1.10.9 F14 Overtemp Overtemperature fault counter
V1.10.10 F25 Watchdog Watchdog fault counter
V1.10.11 F31 IGBT Temp IGBT Temperature fault counter
V1.10.12 F41 IGBT Temp IGBT Temperature fault counter
V1.10.13 F53 Profibus Profibus fault counter
V1.10.14 F57 Thermistor Filter Thermistor fault counter
V1.10.15 Other faults Sum counter of faults F5, F8, F22, F23, F24, F26, F32, F35, F36, F37, F38, F39, F40, F44,
F45, F48, F55, F58
V1.10.16 Total Faults Total number of all faults

2.6 Group 1.11 Bus Control

G1.11 Bus Control


Par code Par name Description
V1.1.1 Run Request Run request is active in Profibus control.
V1.1.2 Profibus Status Profibus Status where “xxxx” is the running message counter.
xxxx.y y = 0 Profibus board is waiting for the parameters from the master.
y = 1 Profibus board is waiting for the configuration from the master.
y = 2 Profibus board is communicating with the master (this is the normal operational
status).

2.7 Group 1.12 Service

G1.12 Service ≥ Engineering password


Par code Par name Description
V1.12.1 HeatSinkTemp Max Shows recorded real heatsink temperature highest peak value during run.
V1.12.2 HeatSinkTemp Min Shows recorded real heatsink temperature lowest peak value when power is connected to
drive.
V1.12.3 IGBT Temp Max Shows recorded calculated IGBT temperature highest peak value.
V1.12.4 IGBT Temperature Shows actual IGBT temperature.

G1.12.5 Max Current ≥ Engineering password


Par code Par name Description
V1.12.5.1 Max Current Shows recorded maximum current.
V1.12.5.2 Max Current Freq Shows frequency at recorded maximum current.

5/15
This document and the information contained herein, is the exclusive property of Konecranes Plc and represents a non-public, confidential and proprietary trade secret that may not
be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of Konecranes Plc. Copyright © (2014)
Konecranes Plc. All rights reserved.
DOC000992/1-EN / 25.09.2014

2.8 Group 1.13 Multimonitor

N1.13.1 Multimonitor
Multimonitor page shows output voltage, output current and output frequency in RUN READY
display in the same time. Monitoring variables can be changed if parameter
P5.5.4 =0 / ChangeEnable. N1.13.1. Auto

400.0V 5.0A
50.00 Hz

6/15
This document and the information contained herein, is the exclusive property of Konecranes Plc and represents a non-public, confidential and proprietary trade secret that may not
be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of Konecranes Plc. Copyright © (2014)
Konecranes Plc. All rights reserved.
DOC000992/1-EN / 25.09.2014

3 GROUP 2 PARAMETERS

3.1 Group 2.1 Basic parameters

G2.1 Basic parameters


Code Name Description Values
P2.1.1 Password Following passwords unlock the parameter values.
Level 1 Locked 0
Level 2 Start-Up 26
Level 3 Engineering 768
Password values cannot be changed.
V2.1.2 Supply Voltage Value of power unit nominal voltage.
F 380V – 500V
V2.1.3 Device Control
P2.1.4 Output frequency [Hz] Output frequency.
0= 50 Hz
1= 60 Hz
P2.1.5 Output Voltage [V] Output voltage.
P2.1.6 DC Start Limit [V] DC start limit. The drive will start when DC start limit is exceeded in AUTO mode (P2.1.8).
Minimum value P2.1.7.
P2.1.7 DC Stop Limit [V] DC stop limit. The drive will stop driving when DC voltage drops below DC stop limit in
AUTO or PANEL mode (P2.1.8).
P2.1.8 Control place Defines how the commands are given.
0= Panel. The commands are given from the keypad.
1= Auto. The drive starts and stops automatically (P2.1.6, P2.1.7)
2= Bus. The commands are given from the fieldbus.
Note! Do not change start function during crane operation. This may cause
hazardous situation.
P2.1.9 Current Limit [A] Defines the maximum output current from the inverter.
To avoid sinus filter overloading, set this parameter according to the rated current of the
sinus filter (normally 1.5...2 x In).
Note! The value must be limited to drive maximum output current (1 minute value).
P2.1.10 Voltage Boost [%] This parameter can be used to compensate the voltage drop in a sinus filter. The amount
of compensation depends on values of P2.1.10 and active output current. Real output
voltage is:
⎛ ⎛ P2.1.10 ×I ⎞ ⎞
P2.1.5 × ⎜1+ ⎜⎜ ⎟ ⎟ , Where I is Active output current.
⎟⎟

⎝ ⎝ 100 × P2.1.9 ⎠ ⎠

7/15
This document and the information contained herein, is the exclusive property of Konecranes Plc and represents a non-public, confidential and proprietary trade secret that may not
be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of Konecranes Plc. Copyright © (2014)
Konecranes Plc. All rights reserved.
DOC000992/1-EN / 25.09.2014

3.2 Group 2.2 Bus Parameters

G2.2 Bus Parameters ≥ Engineering password


Par code Par name Description
P2.2.1 Slave Address Specifies the station address for the drive when used as a slave in the Profibus controlled
by the PLC master. Each slave must have a unique station address. The range of the
address selection is 2-126.
With Engineering password, these parameters can be changed during stop state. With Expert password, these parameters can be
changed also during running. Process data 1 is always output voltage, Process data 2 is always output current and Process data 3 is
always output frequency.
par code par name description
P2.2.2 Process Data 4 0= Not Used
1= Power
2= Power kW
3= HeatSinkTemp
4= FaultCode1+2
5= FaultCode3+4
6= D/A BoardCh1
7= D/A BoardCh2
8= D/A BoardCh3
9= D/A BoardCh4
10 = DC Link Volt
11= U PhaseCurr
12= V PhaseCurr
13= W PhaseCurr
P2.2.3 Process Data 5 Same as P2.2.2.
P2.2.4 Process Data 6 Same as P2.2.2.
P2.2.5 Process Data 7 Same as P2.2.2.
P2.2.6 Process Data 8 Same as P2.2.2.

8/15
This document and the information contained herein, is the exclusive property of Konecranes Plc and represents a non-public, confidential and proprietary trade secret that may not
be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of Konecranes Plc. Copyright © (2014)
Konecranes Plc. All rights reserved.
DOC000992/1-EN / 25.09.2014

3.3 Group 2.3 Protections

G2.3 Protections ≥ Engineering password


Par code Par name Description
P2.3.1 Earth Fault Earth fault protection continuously checks that the sum of the output phase currents is
zero. With this parameter this function be turned off. The overcurrent protection is always
active and protects the inverter from low impedance earth faults.
0= Not Used.
1= Yes. Unit is stopped and fault F3 occurs.
P2.3.2 Line Supervision Line Supervision monitors the supply voltage. With this parameter this function can be
turned off.
0= Not Used.
1= Yes. Unit is stopped and fault F10 occurs.
P2.3.3 Output Supervision Phase supervision of the output continuously checks that the output phases have about
equal current. With this parameter this function can be turned off.
0= Not Used.
1= Yes. Unit is stopped and fault F11 occurs.
P2.3.4 Thermistor Fault With this parameter thermistor function can be turned on.
0= Not used.
1= Yes. Unit is stopped and fault F57 occurs.
P2.3.5 Switching Freq Increasing the switching frequency adds device losses and reduces the continuous load
capacity. If the switching frequency is too low, sinus filter lifetime decreases. The switching
frequency has to be set according to the specification of the filter. Contact factory before
changing switching frequency.
0= Automatic. Switching frequency is selected automatically related on drive power
class.
1= 1.5 kHz
2= 2.5 kHz
3= 3.6 kHz
4= 7.5 kHz
P2.3.6 Unit Max Size Defines the maximum size of the power unit. Contact factory before changing this
parameter.
P2.3.7 Under Volt Limit [V] Defines the undervoltage fault tripping level. When the voltage goes under the value P2.3.7
fault F9 occurs.

3.4 Group 2.4 Expert

G2.4 Expert ≥ Expert password


Par code Par name Description
P2.4.1 Accel Time [s] This value defines the time required for the inverter output frequency to increase from zero
to value P2.1.4. Shorter values than the factory setting must not be used.
P2.4.2 U/f Mid Volt [%] This parameter defines voltage level at mid frequency. Voltage level is given by percentage
of nominal voltage.
P2.4.3 U/f Mid Freq [Hz] This parameter defines middle frequency value.

9/15
This document and the information contained herein, is the exclusive property of Konecranes Plc and represents a non-public, confidential and proprietary trade secret that may not
be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of Konecranes Plc. Copyright © (2014)
Konecranes Plc. All rights reserved.
DOC000992/1-EN / 25.09.2014

3.5 Group 2.5 Laboratory

G2.5 Laboratory ≥ Expert password


Use of laboratory group is limited to R&D purposes only.
Par code Par name Description
P2.5.1 DAC1 Var Type 0= System2. System software variables.
1= Application2. Application software variables.
2= System3. System software variables.
3= Application3. Application software variables.
P2.5.2 DAC1 Address Address of the variable.
P2.5.3 DAC1 Mask Mask of the variable.
P2.5.4 DAC1 Value Actual value of the variable.
P2.5.5 DAC2 Var Type 0= System2. System software variables.
1= Application2. Application software variables.
2= System3. System software variables.
3= Application3. Application software variables.
P2.5.6 DAC2 Address Address of the variable.
P2.5.7 DAC2 Mask Mask of the variable.
P2.5.8 DAC2 Value Actual value of the variable.
P2.5.9 DAC3 Var Type 0= System2. System software variables.
1= Application2. Application software variables.
2= System3. System software variables.
3= Application3. Application software variables.
P2.5.10 DAC3 Address Address of the variable.
P2.5.11 DAC3 Mask Mask of the variable.
P2.5.12 DAC3 Value Actual value of the variable.
P2.5.13 DAC4 Var Type 0= System2. System software variables.
1= Application2. Application software variables.
2= System3. System software variables.
3= Application3. Application software variables.
P2.5.14 DAC4 Address Address of the variable.
P2.5.15 DAC4 Mask Mask of the variable.
P2.5.16 DAC4 Value Actual value of the variable.
P2.5.17 DAC Enable 0= Off
1= On

G2.5.18 DAC Write ≥ Expert password


Use of laboratory group is limited to R&D purposes only.
Par code Par name Description
P2.5.18.1 Index 1 Address 1.
P2.5.18.2 Value 1 Value 1.
P2.5.18.3 Write Mode 1 0= Not Written
1= Power-up
2= Cyclic
P2.5.18.4 Index 2 Address 2.
P2.5.18.5 Value 2 Value 2.
P2.5.18.6 Write Mode 2 See the possible selections from P2.5.18.3.
P2.5.18.7 Index 3 Address 3.
P2.5.18.8 Value 3 Value 3.
P2.5.18.9 Write Mode 3 See the possible selections from P2.5.18.3.
P2.5.18.10 Index 4 Address 4.
P2.5.18.11 Value 4 Value 4.
P2.5.18.12 Write Mode 4 See the possible selections from P2.5.18.3.

10/15
This document and the information contained herein, is the exclusive property of Konecranes Plc and represents a non-public, confidential and proprietary trade secret that may not
be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of Konecranes Plc. Copyright © (2014)
Konecranes Plc. All rights reserved.
DOC000992/1-EN / 25.09.2014

G2.5.19 Datalogger ≥ Expert password


This function makes possible to set the triggering conditions from keypad. PC is needed to get the recorded data out from the inverter. If
triggering conditions are needed to set from PC, P2.5.19.1 Trigger Mode need to be set 0=Off. Contact factory for more information
about datalogger.
Par code Par name Description
P2.5.19.1 Trigger Mode 0= None. Datalogger is not used.
1= First Four. First four events are stored.
2= Last Four. Last four events are stored.
P2.5.19.2 Logger Variable1 0= None.
1= OutputVolt V, Dynacon output voltage. 10 = 1 V.
2= OutputFreqHz, Output frequency. 100 = 1 Hz.
3= OutputCurr %, Percent of nominal current. 1000 = 100 %.
4= Power kW %, Percent of output power. 1000 = 100%.
5= Ready. 1 = Dynacon is on ready state.
6= Ramp Gen Hz, Ramp generator output. 1000 = 100%
7= DCLink Volt V, DC link voltage. 1 = 1 V.
8= Fault Code. Fault code number. For example 1 = F1
9= IGBT Temp °C, IGBT temperature. 1 = 1 °C.
10 = Run Req, Run request from application.
11 = D/A BoardCh1. DAC1 variable.
12 = D/A BoardCh2. DAC2 variable.
P2.5.19.3 Condition 1 0= >
1= >=
2= <
3= <=
4= =
5= <>
P2.5.19.4 Limit 1 Limit for Logger Variable1.
P2.5.19.5 Logic Operator 0= None
1= AND
2= OR
P2.5.19.6 Logger Variable2 0= None.
1= OutputVolt V, Dynacon output voltage. 10 = 1 V.
2= OutputFreqHz, Output frequency. 100 = 1 Hz.
3= OutputCurr %, Percent of nominal current. 1000 = 100 %.
4= Power kW %, Percent of output power. 1000 = 100%.
5= Ready. 1 = Dynacon is on ready state.
6= Ramp Gen Hz, Ramp generator output. 1000 = 100%
7= DCLink Volt V, DC link voltage. 1 = 1 V.
8= Fault Code. Fault code number. For example 1 = F1
9= IGBT Temp °C, IGBT temperature. 1 = 1 °C.
10 = Run Req, Run request from application.
11 = D/A BoardCh1. DAC1 variable.
12 = D/A BoardCh2. DAC2 variable.
P2.5.19.7 Condition 2 0= >
1= >=
2= <
3= <=
4= =
5= <>
P2.5.19.8 Limit 2 Limit for Logger Variable2.
V2.5.19.9 Data Log Counter Counts how many times datalogger has triggered. Resets if any of parameters P2.5.19.1 –
P2.5.19.8 is changed.

11/15
This document and the information contained herein, is the exclusive property of Konecranes Plc and represents a non-public, confidential and proprietary trade secret that may not
be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of Konecranes Plc. Copyright © (2014)
Konecranes Plc. All rights reserved.
DOC000992/1-EN / 25.09.2014

4 GROUP 5 SYSTEM MENU

4.1 Basic information

Basic information
Code Name Description
S5.1 Language English
S5.2 Application Control

4.2 Group S5.3 Copy Parameters

S5.3 Copy Parameters


Code Name Description
S5.3.1 Parameter Sets Not used in DynACon. To save or load a parameter set use G1.7 Parameter Backup.
S5.3.2 Up to keypad Uploads the current user parameters to keypad memory.
S5.3.3 Down from keypad Downloads parameters in keypad memory to user parameters.
P5.3.4 Autom. Backup 0= Yes. Parameter changes are uploaded automatically to keypad.
1= No. Parameter changes are not uploaded automatically to keypad.
The default value of Automatic Backup is 1 = No. That allows keeping a good copy of
parameters in keypad memory.

4.3 Group S5.4 Parameter Comparison

S5.4 Parameter Comparison


Code Name Description
S5.4.1 Set1 These parameters allow you to compare the active parameters to different stored
S5.4.2 Set2 parameter sets. As a result you get a list of the parameters that are different between the
compared parameter sets. The list also shows the values of the parameters that have
S5.4.3 Factory settings
different values between the compared sets.
S5.4.4 Keypad set
With this function you can e.g. check what parameters have been changed after the
delivery of the DynACon and how they have been changed.

Set1 contains the saved user parameters and Set2 contains the factory default parameters
(delivery) of the DynACon. See G1.7 Parameter Backup.

4.4 Group S5.5 Security

S5.5 Security
Code Name Description
P5.5.1 Password This parameter is not used in DynACon. Passwords for different parameter lock levels are
set in parameter P2.1.1.
P5.5.2 Parameter Lock 0= ChangeEnable. Parameter values are unlocked.
1= ChangeDisable. Parameter values are locked.
P5.5.3 Startup wizard 0= No. Startup wizard is not active. This is the default setting in DynACon.
1= Yes. Startup wizard is active. Startup wizard is not used in DynACon.
P5.5.4 [Link] 0= ChangeEnable. Changing the variables of Multimonitor N1.13.1 is enabled.
1= ChangeDisable. Changing the variables of Multimonitor N1.13.1 is disabled.
P5.5.5 OPTAF Remove Default value is 0. Do not change the value.

12/15
This document and the information contained herein, is the exclusive property of Konecranes Plc and represents a non-public, confidential and proprietary trade secret that may not
be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of Konecranes Plc. Copyright © (2014)
Konecranes Plc. All rights reserved.
DOC000992/1-EN / 25.09.2014

4.5 Group S5.6 Keypad Settings

S5.6 Keypad Settings


Code Name Description
P5.6.1 Default Page After timeout or power on, the display returns to the selected page.
P5.6.2 Default Page/OM Not used in DynACon.
P5.6.3 Timeout time After timeout time the display returns to Default Page, if no buttons are pushed.
P5.6.4 Contrast Defines the contrast value of the keypad display.
P5.6.5 Backlight time Defines the backlight time. When no buttons are pushed, after a selected time delay the
backlight of keypad display is turned off.

4.6 Group S5.7 Hardware Settings

S5.7 HW settings
Code Name Description
P5.7.1 InternBrakeRes 0= Not connected. This is the default setting in D2V and must not be changed.
1= Connected. A low capacity internal braking resistor inside inverter. Not used in
D2V.
P5.7.2 Fan control 0= Continuous. The cooling fan is always on.
1= Temperature. The cooling fan is activated when temperature exceeds 60°C. The
fan receives a stop command when the heat sink temperature falls below 55°C.
The fan runs for 1 min after the stop command or power on situation. Also if the
value of this parameter is changed from Continuous to Temperature, the fan still
runs for 1 min regardless of temperature.
2= First start. The cooling fan is activated when drive is started first time after power
on. The fan stays on until the next power off.
3= Calc temp. The cooling fan is activated when IGBT Temperature exceeds 40°C.
The fan receives a stop command when the IGBT Temperature falls below 30°C.
P5.7.3 HMI ACK timeout [ms] 200
Serial communication parameters. Do not change the factory default settings.
P5.7.4 HMI retry 5
P5.7.5 Sine filter Not used in DynACon.

4.7 Group S5.8 System Info

S5.8 System Info

S5.8.1 Total Counters


Code Name Description
C5.8.1.1 MWh counter Shows the total power consumption since the first start.
C5.8.1.2 PwOn Day Counter Shows the total number of power on days.
C5.8.1.3 PwOn hour counter Shows the number of power on hours. The total power on time is PwOn Days + PwOn
hours.

13/15
This document and the information contained herein, is the exclusive property of Konecranes Plc and represents a non-public, confidential and proprietary trade secret that may not
be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of Konecranes Plc. Copyright © (2014)
Konecranes Plc. All rights reserved.
DOC000992/1-EN / 25.09.2014

S5.8.2 Trip Counters


Code Name Description
T5.8.2.1 MWh counter Shows the power consumption after the last reset of this trip counter.
P5.8.2.2 Clr MWh counter Reset = Changing the parameter to Reset value resets the Trip MWh counter
T5.8.2.1. After this the parameter returns to Not Reset value.
Not Reset = Normal value of this parameter. This does not mean that the MWh Trip
counter has never been reset.
T5.8.2.3 PwOn Day Counter Shows the power on days after the last reset of this trip counter.
T5.8.2.4 PwOn hour counter Shows the power on hours after the last reset of this trip counter.
P5.8.2.5 Clr Optime cntr Reset = Changing the parameter to Reset value resets the Trip PwOn Day T5.8.2.3
and PwOn hour T5.8.2.4 counters. After this the parameter returns to Not
Reset value.
Not Reset = Normal value of this parameter. This does not mean that the PwOn day
counter or PwOn hour counters have never been reset.

S5.8.3 Software
Note! The revision codes below are valid only for software version Con3V040.
Code Name Description
I5.8.3.1 Software package NXP00002V182
I5.8.3.2 SystemSw version 22.33.10498 or 33.02.9431
I5.8.3.3 Firmware interf. 4.64
I5.8.3.4 System load Shows the loading status of main CPU in %.

S5.8.4 Applications
Note! The revision codes below are valid only for software version Con3V040.
Code Name Description
D5.[Link] Application id Control3
D5.[Link] Version 4.00
D5.[Link] Firmware interf. 4.63

S5.8.5 Hardware
Code Name Description
I5.8.5.1 Power unit Shows the id code of the power unit.
I5.8.5.2 Unit voltage Nominal voltage of the D2V.
E5.8.5.3 Brake chopper Yes = There is a brake chopper in D2V. Requires a braking resistor. Not used.
No = There is no brake chopper in D2V. Requires an external DC-supply to dissipate the
generated braking power.
E5.8.5.4 Brake resistor Yes = A low capacity internal braking resistor inside inverter. Not used.
No = A high capacity braking resistor outside the inverter. Default setting.
E5.8.5.5 Serial number Serial number of the D2V.

S5.8.6. Expander boards


Code Name Description
E5.8.6.1 A: State = State of basic I/O board in slot A.
Program version = Program version of basic I/O board in slot A.
E5.8.6.2 B: State = State of relay/thermistor board in slot B.
Program version = Program version of relay/thermistor board in slot B.
E5.8.6.3 C: State = State of SSU board in slot C.
Program version = Program version SSU board in slot C.
E5.8.6.4 D: State = State of I/O extension board in slot D.
Program version = Program version of I/O extension board in slot D.
E5.8.6.5 E: State = State of expander board E.
Program version = Program version of expander board E.

14/15
This document and the information contained herein, is the exclusive property of Konecranes Plc and represents a non-public, confidential and proprietary trade secret that may not
be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of Konecranes Plc. Copyright © (2014)
Konecranes Plc. All rights reserved.
DOC000992/1-EN / 25.09.2014

S5.8.7 Debug
Code Name Description
I5.8.7.1 System load Shows the loading status of main CPU.
S5.8.7.2 Parameter log Not used in D2V.
I5.8.7.3 Last event
I5.8.7.4 Event counter
P5.8.7.5 Index 1
V5.8.7.6 Variable 1
P5.8.7.7 Index 2
V5.8.7.8 Variable 2
P5.8.7.9 Index 3
V5.8.7.10 Variable 3
P5.8.7.11 Index 4
V5.8.7.12 Variable 4
P5.8.7.13 Index 5
V5.8.7.14 Variable 5

S5.9 Power monitor


Code Name Description
V5.9.1 IU filtered U phase current.
V5.9.2 IV filtered V phase current.
V5.9.3 IW filtered W phase current.

S5.11 Power multimon.


Code Name Description
V5.11.1 Power multimonitor Output current values.

15/15